Product Overview
Our Shielding Detection Cabin is engineered to provide a secure, interference-free environment for testing and measuring sensitive electronic equipment. With state-of-the-art shielding materials and design, it effectively blocks external electromagnetic signals, ensuring accurate detection and reliable performance in various testing scenarios.
Key Features
Applications
Ideal for use in R&D labs, manufacturing, telecommunications, and medical device testing, where reliable shielding is essential for performance and accuracy.
1、Geometry feature | |
1.1 Inner volume of test chamber | 60m³ |
1.2 Dimensions inside the test chamber | 5000*2200*2200mm(Depth*width*height) |
1.3 Dimensions of the test chamber | Appr 6300*2600*2850mm(Depth*width*height) |
1.4 Test chamber refrigeration unit external dimensions | Appr 2400*1800*2400mm(Depth*width*height) |
1.5 Fresh air system external dimensions | Appr3200*2200*2500mm(Depth*width*height) |
1.6 Vacuum system | Appr1800*2000*2200mm(Depth*width*height) |
2、Main performance indicators | |
2.1 Temperature range | -40℃~+90℃ |
2.2 Pipeline air pressure range | Atmospheric pressure ~50kpa (equivalent to about 5000m) |
2.3 The height corresponding to the the setting pressure | 46.54kpa→6100m |
57.30kpa→4550m | |
69.66kpa→3050m | |
79.50kpa→2000m | |
2.4 Humidity range | Relative humidity: 20%R.H~95%R.H (No-load at normal pressure) |
2.5 Temperature range for humidity operation | 20℃~65℃, 20%R.H~95%R.H (No-load at normal pressure) |
2.6 Degree of temperature fluctuation | ≤±0.5℃(atmospheric pressure, no-load) |
2.7 Degree of temperature deviation | ≤±2.0℃(atmospheric pressure, no-load) |
2.8 Degree of humidity deviation | +2%~-3%R.H(humidity>75%R.H) |
±5%R.H(humidity<75%R.H) | |
2.9 Degree of air pressure deviation | ≤±2kpa |
2.10 Cooling rate | ≥1℃/min(+40℃~-40℃) |
2.11 Heating rate | ≥1℃/min(-40℃~+70℃) |
2.12 Load | hydrogen fuel cell |
weight:≤400kg | |
power:150kw | |
Radiator: placed in the cabin |