● Precision machining frame.
● Precision parallelism ±0.02mm, flatness ±0.02mm.
● Section-compartmentalized heating, temperature control uniformity±0.02; control accuracy rate 1%
● The accuracy of stroke control is high, and the repetitive precision is controlled in 0.1mm.
● Extremely low levels of noise and vibration.
● Hydraulic system equipped with fault monitoring device.
● PLC control system with digital display.
● High operating temperature.
No. |
Item |
Unit |
Data |
|||||
1 |
Nominal Pressure |
KN |
20 |
50 |
100 |
200 |
||
2 |
Distance between Upper&Lower Platform |
mm |
300 |
|||||
3 |
Max Stroke of Cylinder |
mm |
300 |
|||||
4 |
Available Size of Platform |
Left& |
mm |
300 |
400 |
500 |
550 |
|
|
|
Front& |
mm |
300 |
400 |
500 |
550 |
|
5 |
Running Speed of Platform |
Fast Running Downwards |
mm/s |
1-40 |
||||
|
|
Slow Running Downwards |
mm/s |
0.01-3 |
||||
|
|
Return Stroke |
mm/s |
1-40 |
||||
6 |
Parallelism Degree of Upper&lower Platform |
mm |
±0.02 |
|||||
7 |
Working Platform Flatness |
mm |
±0.02 |
|||||
8 |
Pressure control Precision |
KN |
±1% |
|||||
9 |
Max Temperature of Hot Plate |
℃ |
250 |
|||||
10 |
Heating Rate(Controllable) |
℃/min |
1-6 |
|||||
11 |
|
Pressure Gradient |
KN |
9 |
||||
12 |
Temp Gradient |
℃ |
9 |
|||||
13 |
Time Gradient |
S |
9 |
|||||
14 |
Temp Display Control Precision |
℃ |
±0.5 |
|||||
15 |
Hot Plate Flat Temp Error |
℃ |
±2 |
|||||
16 |
Equipment Pressure Maintaining & Drop |
MPa |
≤1/2 |
|||||
17 |
Motor Power(approximate) |
KW |
Adjusting the power of motor in accordance with the speed 1-15KW |
|||||
18 |
Heating Power |
KW |
10 |
15 |
20 |
25 |
||
19 |
Distance between Lower Hot plate and ground |
mm |
≤750 |
800 |
||||
20 |
Total Weight |
KG |
≦1000 |
2000 |
3000 |
4000 |